مواشي وحيوانات وطيور/مستلزمات دواجن/كل الحراج/دجاج

Temperature and Humidity Controller for Incubators

Taif
Updated 12 hr. ago
ا
80
Accurate temperature and humidity controller for incubators 220 Volts Limited quantity The part shown in the image is a dual digital controller for measuring and setting temperature and humidity, model XK-W1099. This device is widely used in incubators, refrigerators, and laboratories to provide an ideal and stable environment. Setup and Programming Guide The device has two separate screens; the left side (OUT1) is for controlling temperature in degrees Celsius (°C), and the right side (OUT2) is for controlling relative humidity (%RH). 1. Setting Temperature (OUT1) Set Operating Temperature (Start Temperature): Press the up arrow button (for temperature) once to display the current start temperature. Press and hold the same button for 3 seconds until the numbers start flashing. Use the up and down arrow buttons to set the desired temperature for the heater or cooler to turn on. Set Stop Temperature: Press the down arrow button once to display the current stop temperature. Press and hold the same button for 3 seconds until the screen flashes. Use the arrows to set the temperature at which the device will turn off. 2. Setting Humidity (OUT2) Set Operating Humidity (Start Humidity): Press the up arrow button (for humidity) once to view the start value. Press and hold for 3 seconds until the indicator starts flashing. Set the desired percentage for the humidifier to turn on using the arrows. Set Stop Humidity: Press the down arrow button once to view the stop value. Press and hold for 3 seconds until the reading flashes. Set the humidity percentage at which the device will turn off. Additional Functions and Important Features Heating or Cooling / Humidifying or Dehumidifying Mode: If the start temperature is lower than the stop temperature, the device operates in heating mode (or humidifying). If the start temperature is higher than the stop temperature, the device automatically switches to cooling mode (or dehumidifying). Calibration: If you notice a difference between the device's reading and another accurate meter's reading, press the up and down arrow buttons simultaneously for the same side for 3 seconds to adjust the difference value. Factory Reset: To restore the original settings, press and hold the down arrow (1) and down arrow (2) buttons together for 3 seconds.
Temperature and Humidity Controller for Incubators 0Temperature and Humidity Controller for Incubators 1